Triton CDS (T3CDS) | Ex eb, Ex db, Ex nR & Ex ta | Explosive Atmosphere Cable Gland

For all types of Armoured Cables

CMP
, ,

Description

Globally Approved, Explosive Atmosphere Cable Gland

• Fully sequential, three step installation procedure
• Reduces installation times, cost & risk
• Direct & remote installation
• Unique compensating displacement seal system (CDS)
– Metal-to-metal installation every time regardless of cable diameter
• Designed to prevent Coldflow, see CMP Technical Document TS002 (available upon request)
• Integral protected deluge seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• -60°C to +130°C
• Globally marked, IECEx, ATEX, UL & cCSAus
• EMC tested

† Grooved Cone (X) is predominantly used for Wire Braid (e.g. GSWB, TCWB), Steel Tape Armour (STA, DSTA) and Aluminium Strip Armour (ASA) but is also suitable for Single Wire Armour (SWA), Aluminium Wire Armour (AWA) and Pliable Wire Armour (PWA) if the range is outside that of the Stepped Cone (W).

Note: Grooved Cone (X) dimensions shown in the Cable Gland Selection Table below are for a double wire strand of braid armour cables. Tapes can also be doubled over. For cables that have only a single layer of armour such as SWA the clamping range should be used as shown in the table below.

Stepped (W) Cone is suitable for Single Wire Armour (SWA), or Aluminium Wire Armour (AWA) cables.

 

Technical Data

Design Specification BS 6121:Part 1:1989, IEC 62444, EN 62444
Mechanical Classifications* Impact = Level 8, Retention = Class D
Enclosure Protection IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only
Electrical Classifications* Category B (Category A when used with braid, tape or pliable wire armour cables)
ATEX Certificate CML 18ATEX1326X
CML 18ATEX4318X
UKEX Certificate CML 21UKEX1258X,CML 21UKEX4259X
Code of Protection  II 2G, II 1D, Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da,
II 3G Ex nR IIC Gc,  I M2, Ex db I Mb, Ex eb I Mb
Compliance Standards EN60079-0,1,7,15,31
IECEx Certificate IECEx CML 18.0183X
Code of Protection Ex db IIC Gb, Ex eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da, Ex db I Mb, Ex eb I Mb
Compliance Standards IEC 60079-0,1,7,15,31
cCSAus Certificate (20s16 – 90) 1310517
CSAus Code of Protection Class II, Div 2, Groups E,F and G, Class III, Enclosure Type 4X, Oil Res II
Class I, Zone 1, AEx e II, AEx nR II
Class I, Zone 1, AEx e II, AEx nR II
cCSA Code of Protection Class I, Div 2, Groups A,B,C and D, Class II, Div 2, Groups E,F and G, Class III, Enclosure Type 3, 4 and 4X,
Ex d IIC, Ex e IIC, Ex nR II
Compliance Standards CAN/CSA-C22.2 No 0, 18, 25, 30, 94, 174, CAN/CSA-E60079-0, 1, 7,
ANSI/UL 514B Ed 5, ANSI/UL 50 Ed 11, ANSI/UL 2225 Ed 4, UL60079-0, 1, 7
UL Certificate (20s16 – 90) E200163
Code of Protection Class I, Zone 1, AEx e II
Compliance Standards UL514B
ECAS Certificate 24-03-106290/E24-03-110155/NB0007
EAC Certificate (Formerly GOST R, K & B) C-GB.AД07.B.04599/22
UkrSEPRO CU 19.0371X
CCC Certificate 2020322313002527
CCOE / PESO (India) Certificate Ex d: P548696Ex e: P533772 Ex nR: P548695
INMETRO Certificate TÜV 11.0374X
RETIE Certificate 03866
Marine Approvals LRS: 01/00172 (E4)DNV: TAE00000YABS: 20-LD1948801-PDABV: 43180/A1
SANS MS-XPL21804 21.0011X
Ingress Protection Rating ** IP66, IP67 & IP68
Deluge Protection Compliance DTS01 : 91
Cable Gland Material Brass, Electroless Nickel Plated Brass, Aluminium, Stainless Steel
Seal Material CMP SOLO LSF Halogen Free Thermoset Elastomer
Cable Type Single Wire Armour (SWA), Aluminium Wire Armour (AWA), Pliable Wire Armour (PWA), Steel Tape Armour (STA), Aluminium Strip Armour (ASA), Screened Flexible (EMC) Wire Braid (e.g. CY/SY), Wire Braid Armour (e.g. SWB)
Armour Clamping Reversible Armour Cone & AnyWay Universal Clamping Ring
Sealing Technique Inner Bedding Sealing Ring: Compensating Displacement Seal (CDS), Outer Sheath Sealing Ring : Load Retention Seal (LRS)
Sealing Area(s) Cable Inner Bedding & Outer Cable Sheath
Optional Accessories LocknutsEarth TagsSerrated WashersEntry Thread SealsShrouds,Ingress Discs
Optional Installation Tools SpannersArmour Former Tool

Note: * Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** When CMP installation accessories are used. Refer to Maintaining a Seal for further information.
*** IP68 tested to a minimum depth of 30 metres for 12 hours, alternate depths / durations can be provided upon request